An understanding of pump performance curves is an
important part of a pump installer’s storehouse of knowledge. It is crucial to
pump selection, and can mean the difference between an efficient water system,
and one that is marginally operational, leading to frequent
callbacks.
Last month, we began this series on pump selection with a look at the simplest
of pump curves, those showing only pressure and flow, as typically are seen for
residential submersible pumps. When the capacity and horsepower requirements of
a pumping system go up, additional information often is needed, such as pump
efficiency, horsepower and NPSH (net positive suction head). This month, we
will begin to look at these additional factors.
But first, let’s see how pump curves are created. The pump curves we see in
pump manufacturers’ catalogs are a visual representation of test data collected
in their labs. To collect this data, a technician connects the pump to a test
station similar to the one depicted in Figure 1, containing a pressure gauge, a
valve to regulate the flow, and a flow meter to measure the flow rate.
To plot a pump’s curve, the technician starts with a piece of graph paper. The
horizontal axis represents the flow rate, and the vertical axis shows pressure.
In the United States,
flow is measured in gallons per minute, and pressure is measured in pounds per
square inch (PSI), or feet of water. The first point on the curve is generated
by closing the regulating valve all the way to “deadhead” the pump, and
measuring the pressure on the gauge. Next, the valve is opened slowly until,
say, 5 gpm shows on the flow meter, and the resulting pressure is recorded on
the graph. This procedure is repeated until the regulating valve is wide open,
and the pump is operating at open discharge. The resulting curve is the
simplest form of a pump curve.
With a good pressure gage and a flow meter, you can test the performance of a
pump in your own shop and create a curve. This might come in handy some time if
you find yourself in a performance dispute with a customer or pump
manufacturer, and wish to verify the pump’s performance for yourself. For more
information on how to build a pump test station, check out an earlier article
in this publication by going to www.thedriller.com and searching “Making a
Submersible Pump Test Station.”
As mentioned above, there are three other factors that
could be considered when selecting a pump – efficiency, horsepower and NPSH.
These are graphically represented as shown on Figure 2 as the efficiency curve,
the horsepower curve and the NPSH curve. The NPSH curve will be discussed in
detail in this column in the June 2011 issue ofNational Driller.
The efficiency curve shows the relative cost to run the pump. It is generated
by measuring the amount of energy consumed by a pump at various flow rate
points, relating that to the amount of work done (GPM and head) at each point,
and calculating an efficiency number. Pump efficiency always is important, but
it is particularly important when you are pumping a lot of water. If you have
several pumps from which to choose for a particular job, the more expensive
pump might pay for itself in a short period of time through energy savings if
it is more efficient.
Horsepower curves are essential in selecting the proper pump motor, and can be
used in the same way as the efficiency curve to determine the relative
operating cost of a particular pump. For example, when we take electric motor
efficiency into account, one horsepower equals approximately three-quarters of
a kilowatt (750 watts). To estimate the annual operating cost of a pump, find
the horsepower at the operating point, and multiply by the number of hours per
year you expect the pump to run. This number multiplied by 0.75 gives the
number of kilowatt-hours of electricity consumed by the pump in a year.
Multiply this number by the cost of a kilowatt, and you have an estimate of the
annual cost of the energy to run the pump.
Example: Referring to Figure 2, at 70 gpm, the motor is drawing 3 HP. If we
expect to run the pump 5,000 hours per year, this pump would use 11,250 kW
hours per year (3 HP x 5,000 hrs. x 0.75 = 11,250). At $0.20 per kW hour, the
annual operating cost for this pump is $2,250 for electricity.
Now, if you could find another, more efficient pump that used only 2.5 HP to
pump the required amount of water, the annual cost of electricity will be 2.5 x
5,000 x 0.75 x $0.20 = $1,875 per year – a savings of $375 over the first pump.
Factor in the cost difference of the two pumps, and you might find the more
efficient, more expensive pump would cost less over the life of the
pump.
Next month, we will continue this series on pump curves with a look at
composite curves and pump charts. ’Til then ….